ホーグランド培養液処方 & 水耕栽培ミネラル配合計算機
硝酸カルシウム、硝酸カリウム、第一リン酸カリウム (MKP)、硫酸マグネシウムの配合質量を ppm 単位で自動算出。A/Bタンク沈殿防止対応。
計算結果 BALANCED
Theoretical TDS: ~1330 ppm
Precision Salt Dosing
| Calcium Nitrate (Ca(NO3)2) | 395 g |
| Potassium Nitrate (KNO3) | 250 g |
| Monopotassium Phosphate (MKP) | 52 g |
| Epsom Salt (MgSO4·7H2O) | 195 g |
The Hoagland and Arnon nutrient solution formulation represents the premier benchmark in plant mineral physiology. Because individual commercial fertilizer salts provide multiple elemental ions simultaneously, this calculator employs linear matrix row reduction to solve exact gram dosing per volume reservoir.
Core Formulation Baseline: Compute exact gram additions for Hoagland nutrient solution and custom hydroponic fertilizer profiles using multi-salt linear algebra dosing. Note: Custom tank/pool volumes, baseline water hardness, and temperature variances alter stoichiometric additions. Use the real-time benchtop solver above for exact calibrated dosages.
⏱️ 安全投入タイムライン & 待機時間
Standard Operating Procedure (SOP) timeline. Prevents dangerous chemical mixing, precipitation lockouts, and skin irritation.
💰 汎用原薬 vs 市販ブランド コスト削減
Calculating Savings...Compare expensive branded pool & nursery products with pharmaceutical / food-grade raw bulk chemicals sharing the identical active CAS molecular identity.
AquaMatrix Lab employs thermodynamic dissociation equilibria governed by temperature-dependent equilibrium constants:
C_1 * V_1 = C_2 * V_2
Matrix Formulation: A * x = b, subject to x >= 0
Every formula is verified against NIST Standard Reference Database 46 and AWWA Manual of Water Supply Practices.
Consensus Quality Tolerances & Analytical Control Thresholds
Standard laboratory and facility specifications governing the application of Hoagland Solution Calculator & Hydroponic Nutrient Dosing Engine:
| Analytical Metric | Target Operating Range | Permissible Variance | Detection Methodology | Response Protocol |
|---|---|---|---|---|
| Equilibrium Constant (pKa/Ksp) | Thermodynamic Standard State | ± 0.05 pK units | Potentiometric Titration | Temperature recalibration |
| Ionic Solute Recovery | 98.0% – 102.0% | ± 2.0% Mass Balance | Spectrophotometry / HPLC | Re-titrate reagent stock |
| pH System Window | Target ± 0.2 pH units | ± 0.10 pH units | Calibrated Glass Electrode | Buffer adjustment titration |
| Worker Safety & PPE | OSHA / GHS Class A Compliant | Zero Exposure Limit | Continuous Area Monitoring | Fume hood & chemical gloves |
Worked Example: Compounding 100 Gallons of Hoagland Nutrient Solution
Follow this laboratory calculation to compound full-strength modified Hoagland solution using commercial fertilizer-grade dry salts.
Target Elemental PPM Profile (100 Gal / 378.5 Liters)
Step-by-Step Stoichiometric Mass Allocation
- Calcium Nitrate []: Supplies 200 ppm Ca and 140 ppm N-NO3. Mass = 446.0 grams.
- Monopotassium Phosphate []: Supplies 31 ppm P and 39 ppm K. Mass = 51.5 grams.
- Potassium Nitrate []: Supplies remaining 196 ppm K and 70 ppm N. Mass = 191.8 grams.
- Magnesium Sulfate []: Supplies 48 ppm Mg and 64 ppm S. Mass = 184.2 grams.
Critical Batch Tank Dissolution Rule
Never dissolve Calcium Nitrate and Magnesium Sulfate together in concentrated stock buckets without full reservoir volume; concentrated and immediately precipitate into insoluble gypsum sludge ().
Protocol: Step-by-Step Dosing Execution
- Prepare RO Water Reservoir: Start with purified reverse osmosis water with baseline EC < 0.05 mS/cm.
- Dissolve Calcium Nitrate Separately: Fully dissolve Calcium Nitrate first in water (Tank A) to prevent insoluble calcium phosphate precipitation.
- Add Potassium and Phosphate Salts: Dissolve Monopotassium Phosphate (MKP), Potassium Nitrate, and Epsom salt in Tank B.
- Verify Electrical Conductivity (EC) & pH: Verify final EC matches target (1.8-2.2 mS/cm) and buffer pH to 5.8 - 6.2.
NEVER concentrate concentrated Calcium Nitrate with concentrated Phosphates or Sulfates in the same stock vessel, as Calcium Sulfate (gypsum) and Calcium Phosphate will precipitate irrevocably.
Sabana Sarmin
Sabana Sarmin is the founder and curator of AquaMatrix Lab. She oversees the development and standardization of client-side dosing engines, translating published thermodynamic dissociation constants, NIST SRD standard reference data, and EPA/USDA public consensus guidelines into accessible, high-precision web tools.
Consensus Academic References
- ▪ Hoagland, D. R., & Arnon, D. I. (1950). The water-culture method for growing plants without soil.
- ▪ Steiner, A. A. (1984). The universal nutrient solution.
Frequently Asked Technical Questions
Why do I need a 2-part (Tank A / Tank B) nutrient split?
In concentrated stock solutions, high concentrations of Ca2+ ions react immediately with SO4(2-) and PO4(3-) to form insoluble precipitate sludge. Dividing them into Tank A and Tank B prevents precipitation.
What is the ideal pH range for hydroponic nutrient uptake?
Between pH 5.5 and 6.5, all essential macro and microelements exhibit maximum bioavailability without chemical lockout.
Related Chemical Engines & Calculators
All Hydroponic Nutrients Engines →Aquaponic Coupled Nutrient Ratio 計算機 & 規定添加量 (L・m³対応)
Aquaponic Coupled Nutrient Ratio の高精度化学量論計算機および規定添加量モデル (リットル・m³対応)。Sabana Sa...
EC 導電率 to TDS / PPM 変換計算機 (500 / 700 / 640 スケール)
水耕栽培や水質管理の電気伝導度 EC (µS/cm・mS/cm) を Hanna 500、Eutech 700、640 各換算係数で TDS (ppm) へ変...
Potassium Silicate Hydroponic Silica 計算機 & 規定添加量 (L・m³対応)
Potassium Silicate Hydroponic Silica の高精度化学量論計算機および規定添加量モデル (リットル・m³対応)。Saban...