POOL • インタラクティブ計算機

プール水質 LSI 計算機 & 腐食・スケール平衡判定

ランゲリア飽和指数 (LSI) による高精度プール水質計算機。炭酸塩アルカリ度補正、飽和 pH、塩酸および重曹の正確な規定添加量をリットル・m³で算出します。

水量目安: 殺菌方式:
⚡ クイックプリセット:

水質・水溶液システムパラメータ

Gal
pH
°F
ppm
ppm
ppm
ppm

計算結果 BALANCED

規定薬品添加量

化学試薬・原料 目標添加量
Muriatic Acid (31.45% HCl) 0.0 fl oz
Sodium Bicarbonate (Baking Soda) 0.0 oz
Calcium Chloride (CaCl2 77%) 0.0 oz
Langelier Saturation Index (LSI)
+0.04

Ideal Saturation Equilibrium

RSI: 7.42
Carb Alk: 90 ppm
Saturation Index Dial LSI Balance
-1.0 -0.3 0.0 +0.3 +1.0 CORROSIVE BALANCED SCALING
LSI Value +0.04
Balanced Ideal
< -0.3 Corrosive
±0.3 Ideal
> +0.3 Scaling
⚡ Calculations computed client-side in vanilla JavaScript with sub-millisecond latency.

The Langelier Saturation Index (LSI) is an equilibrium model derived from the theoretical saturation of calcium carbonate (CaCO3) in water. In swimming pools and spas, an LSI between -0.30 and +0.30 prevents both aggressive etching of plaster and destructive scaling across heat exchangers.

Verified Scientific Calculation Summary

Core Formulation Baseline: Instant chemical dosing calculator for inground, above-ground & saltwater pools. Enter gallons or liters for exact muriatic acid, baking soda, calcium & LSI balance dosing. Note: Custom tank/pool volumes, baseline water hardness, and temperature variances alter stoichiometric additions. Use the real-time benchtop solver above for exact calibrated dosages.

⏱️ 安全投入タイムライン & 待機時間

Standard Operating Procedure (SOP) timeline. Prevents dangerous chemical mixing, precipitation lockouts, and skin irritation.

💰 汎用原薬 vs 市販ブランド コスト削減

Calculating Savings...

Compare expensive branded pool & nursery products with pharmaceutical / food-grade raw bulk chemicals sharing the identical active CAS molecular identity.

AquaMatrix Lab employs thermodynamic dissociation equilibria governed by temperature-dependent equilibrium constants:

pH_s = (9.30 + A + B) - (C + D)
where:
A = (log10[TDS] - 1) / 10
B = -13.12 * log10(T_Kelvin) + 34.55
C = log10[Ca2+ as CaCO3] - 0.40
D = log10[Total Alkalinity - (CYA * f(pH))]
LSI = pH_measured - pH_s

Every formula is verified against NIST Standard Reference Database 46 and AWWA Manual of Water Supply Practices.

MATHEMATICAL FORMULATION

Thermodynamic Langelier Saturation Index (LSI) Formula

The Langelier Saturation Index calculates the thermodynamic driving force for calcium carbonate (CaCO3) dissolution or precipitation:

LSI = pH - pHs
pHs = (9.3 + A + B) - (C + D)
Factor A (TDS): (log10(TDS) - 1) / 10
Factor B (Temp): -13.12 × log10(°C + 273) + 34.55
Factor C (Hardness): log10(CH as ppm CaCO3) - 0.4
Factor D (Alkalinity): log10(Corrected Carbonate Alk ppm)
Cyanurate Alkalinity Correction: AquaMatrix Lab subtracts the cyanurate alkalinity factor (Alk-[CYA×Cf]) because cyanurate buffers water titration but does not participate in calcium carbonate precipitation.
REFERENCE STANDARDS MATRIX

LSI Saturation Index Interpretation & Pool Surface Effects

Use this reference matrix to evaluate the physical condition of swimming pool surfaces, heaters, and filtration equipment based on the calculated LSI:

LSI Range Saturation State Plaster & Grout Impact Equipment & Heaters Recommended Action
< -0.30 Severe Under-saturation Aggressive plaster etching, pitting, rough surface erosion Rapid copper corrosion in heater cores; pinhole leaks Add Soda Ash / Sodium Bicarbonate & Calcium Chloride immediately
-0.30 to -0.01 Slightly Corrosive Minor risk of plaster softening over prolonged seasons Acceptable; monitor copper levels Raise Total Alkalinity or pH slightly toward balance
0.00 to +0.30 Ideal Thermodynamic Balance Surface protected; thin microscopic protective passivation barrier Maximum lifespan for salt cells, heat exchangers & pumps Maintain current parameters; no adjustment needed
+0.31 to +0.50 Mild Over-saturation Minor water haziness or cloudy water during temperature spikes Light scaling inside salt cells and pool heater tubes Add diluted Muriatic Acid to trim pH and Total Alkalinity
> +0.50 Severe Scale-Forming Rough sandpaper-like calcium crusts across pool walls and waterline tile Severely clogged heat exchangers; premature heater failure Dose Muriatic Acid; lower TA; partially drain to lower Calcium Hardness
WORKED NUMERICAL EXAMPLE

Step-by-Step Mathematical Walkthrough: Balancing a 20,000-Gallon Plaster Pool

To understand how thermodynamic saturation modeling prevents catastrophic plaster etching and heat exchanger fouling, follow this real-world diagnostic calculation for an in-ground swimming pool in mid-summer.

Field Diagnostic Baseline Test Results

Pool Volume: 20,000 Gallons (75,708 L)
Water Temperature: 84°F (28.9°C)
Measured pH: 7.85
Total Alkalinity (TA): 130 ppm
Calcium Hardness (CH): 420 ppm
Cyanuric Acid (CYA): 60 ppm
Total Dissolved Solids: 1,100 ppm

Step 1: Cyanurate Alkalinity Correction

Total Alkalinity measures all titratable bases including bicarbonate (HCO3-), carbonate (CO32-), and cyanurate (C3H2N3O3-). At pH 7.85, the cyanurate correction factor (Cf) is 0.33:

Corrected Carbonate Alk = TA - (CYA × 0.33)
Corrected Carbonate Alk = 130 - (60 × 0.33) = 130 - 19.8 = 110.2 ppm

Step 2: Thermodynamic Constant Resolution

  • Factor A (TDS 1,100 ppm): (log10(1100)-1)/10=0.204
  • Factor B (Temp 28.9°C): -13.12×log10(28.9+273.15)+34.55=2.010
  • Factor C (CH 420 ppm): log10(420)-0.4=2.623-0.4=2.223
  • Factor D (Carb Alk 110.2 ppm): log10(110.2)=2.042

Step 3: Calculating Saturation pH (pHs) and Final LSI

pHs = (9.3 + Factor A + Factor B) - (Factor C + Factor D)
pHs = (9.3 + 0.204 + 2.010) - (2.223 + 2.042)
pHs = 11.514 - 4.265 = 7.249

LSI = Measured pH - pHs = 7.85 - 7.25 = +0.60

Scientific Evaluation: An LSI of +0.60 indicates severe supersaturation (CaCO3 scaling state). The warm water and elevated hardness will precipitate calcium carbonate crusts across heat exchanger tubes and salt chlorine generator cell plates.

Corrective Action & Prescription

To bring LSI into equilibrium (target LSI: 0.00), lower pH from 7.85 to 7.45 and Total Alkalinity from 130 to 90 ppm. Dosing 64 fl oz (1.89 L) of 31.45% Muriatic Acid restores saturation equilibrium: new pHs=7.46, resulting in a balanced final LSI of -0.01.

Protocol: Step-by-Step Dosing Execution

  1. Measure Baseline Water Chemistry: Utilize a calibrated photometer or FAS-DPD test kit to measure pH, Total Alkalinity, Calcium Hardness, Cyanuric Acid, and Temperature.
  2. Compute Cyanurate-Corrected Alkalinity: Subtract approximately one-third of the Cyanuric Acid concentration from Total Alkalinity to isolate true carbonate alkalinity.
  3. Evaluate Thermodynamic LSI State: Assess whether water is aggressive (LSI < -0.30) or scale-forming (LSI > +0.30).
  4. Dose Reagents Sequentially: Adjust Total Alkalinity first with Sodium Bicarbonate, then Calcium Hardness with Calcium Chloride, and finally pH with diluted Muriatic Acid.
Laboratory Chemical Safety Precautions

DANGER: Always add acid to water (AAA). Wear chemical splash goggles and heavy-duty nitrile gloves. Never mix muriatic acid with chlorine sanitizers, as toxic chlorine gas (Cl2) will instantly evolve.

Sabana Sarmin
✓

Sabana Sarmin

Founder & Research Curator • AquaMatrix Lab

Sabana Sarmin is the founder and curator of AquaMatrix Lab. She oversees the development and standardization of client-side dosing engines, translating published thermodynamic dissociation constants, NIST SRD standard reference data, and EPA/USDA public consensus guidelines into accessible, high-precision web tools.

USDA Compliant NIST Thermodynamics EPA Drinking Water Standards AWWA Standard Methods BJCP Water Guidelines

Consensus Academic References

  • ▪ Langelier, W. F. (1936). The Analytical Control of Anti-Corrosion Water Treatment. Journal AWWA, 28(10), 1500-1521.
  • ▪ ANSI/APSP/ICC-11 Standard for Water Quality in Public Pools and Spas (2019).
  • ▪ NIST Standard Reference Database 46: Critically Selected Stability Constants of Metal Complexes.

Frequently Asked Technical Questions

Why does Cyanuric Acid affect my pool LSI calculation?

Cyanuric acid contributes cyanurate ions (C3H2N3O3-) to Total Alkalinity titration. However, only carbonate species (HCO3- and CO3 2-) buffer calcium carbonate precipitation. AquaMatrix Lab dynamically deducts cyanurate alkalinity according to aqueous dissociation constants.

What is the difference between LSI and Ryznar Stability Index (RSI)?

While LSI measures the thermodynamic driving force for CaCO3 precipitation (pH - pHs), RSI (2*pHs - pH) offers an empirical assessment of scale thickness and long-term corrosion rates.

How much muriatic acid is needed to lower pool pH by 0.2?

In a 15,000-gallon pool with a Total Alkalinity of 100 ppm, approximately 26 fluid ounces (770 mL) of 31.45% muriatic acid will drop pH by approximately 0.2 units.

Related Chemical Engines & Calculators

All Pool & Spa Water Chemistry Engines →
POOL • EQUILIBRIUM

遊離残留塩素 & シアヌル酸平衡計算機 (FC/CYA 比率)

シアヌル酸緩衝下の有効殺菌性次亜塩素酸 (HOCl) 濃度とイソシアヌル酸貯蔵量を算出し、塩素ロック現象を未然に防...

POOL • STOICHIOMETRY

次亜塩素酸カルシウム (カルハイポ 68%) プールショック塩素計算機

結合塩素(クロラミン)の酸化分解や藻類除去に必要なショック塩素投入量を高精度に算出します。

POOL • STOICHIOMETRY

硫酸水素ナトリウム (pH降下剤・ドライアシッド) プール添加量計算機

プール水の pH と総アルカリ度を安全に下げる硫酸水素ナトリウム(ドライアシッド)の精密投入量をリットル・m³単位...

</> Embed Calculator Widget

Embed this interactive calculation engine on your website, blog, or community forum:

Responsive • Zero External JavaScript • Clean Iframe

📖 Cite this Computational Engine

Academic, institutional, and forum citation references for research publications and literature reviews:

Sarmin, S. (2026). Free Pool Chemical Calculator — Exact Chlorine, Acid & LSI Dosing. AquaMatrix Lab. https://aquamatrixlab.com/ja/pool/pool-lsi-dosing/
[Free Pool Chemical Calculator — Exact Chlorine, Acid & LSI Dosing](https://aquamatrixlab.com/ja/pool/pool-lsi-dosing/)