プール水質 LSI 計算機 & 腐食・スケール平衡判定
ランゲリア飽和指数 (LSI) による高精度プール水質計算機。炭酸塩アルカリ度補正、飽和 pH、塩酸および重曹の正確な規定添加量をリットル・m³で算出します。
計算結果 BALANCED
規定薬品添加量
| 化学試薬・原料 | 目標添加量 |
|---|---|
| Muriatic Acid (31.45% HCl) | 0.0 fl oz |
| Sodium Bicarbonate (Baking Soda) | 0.0 oz |
| Calcium Chloride (CaCl2 77%) | 0.0 oz |
Ideal Saturation Equilibrium
The Langelier Saturation Index (LSI) is an equilibrium model derived from the theoretical saturation of calcium carbonate (CaCO3) in water. In swimming pools and spas, an LSI between -0.30 and +0.30 prevents both aggressive etching of plaster and destructive scaling across heat exchangers.
Core Formulation Baseline: Instant chemical dosing calculator for inground, above-ground & saltwater pools. Enter gallons or liters for exact muriatic acid, baking soda, calcium & LSI balance dosing. Note: Custom tank/pool volumes, baseline water hardness, and temperature variances alter stoichiometric additions. Use the real-time benchtop solver above for exact calibrated dosages.
⏱️ 安全投入タイムライン & 待機時間
Standard Operating Procedure (SOP) timeline. Prevents dangerous chemical mixing, precipitation lockouts, and skin irritation.
💰 汎用原薬 vs 市販ブランド コスト削減
Calculating Savings...Compare expensive branded pool & nursery products with pharmaceutical / food-grade raw bulk chemicals sharing the identical active CAS molecular identity.
AquaMatrix Lab employs thermodynamic dissociation equilibria governed by temperature-dependent equilibrium constants:
where:
A = (log10[TDS] - 1) / 10
B = -13.12 * log10(T_Kelvin) + 34.55
C = log10[Ca2+ as CaCO3] - 0.40
D = log10[Total Alkalinity - (CYA * f(pH))]
LSI = pH_measured - pH_s
Every formula is verified against NIST Standard Reference Database 46 and AWWA Manual of Water Supply Practices.
Thermodynamic Langelier Saturation Index (LSI) Formula
The Langelier Saturation Index calculates the thermodynamic driving force for calcium carbonate () dissolution or precipitation:
pHs = (9.3 + A + B) - (C + D)
LSI Saturation Index Interpretation & Pool Surface Effects
Use this reference matrix to evaluate the physical condition of swimming pool surfaces, heaters, and filtration equipment based on the calculated LSI:
| LSI Range | Saturation State | Plaster & Grout Impact | Equipment & Heaters | Recommended Action |
|---|---|---|---|---|
| < -0.30 | Severe Under-saturation | Aggressive plaster etching, pitting, rough surface erosion | Rapid copper corrosion in heater cores; pinhole leaks | Add Soda Ash / Sodium Bicarbonate & Calcium Chloride immediately |
| -0.30 to -0.01 | Slightly Corrosive | Minor risk of plaster softening over prolonged seasons | Acceptable; monitor copper levels | Raise Total Alkalinity or pH slightly toward balance |
| 0.00 to +0.30 | Ideal Thermodynamic Balance | Surface protected; thin microscopic protective passivation barrier | Maximum lifespan for salt cells, heat exchangers & pumps | Maintain current parameters; no adjustment needed |
| +0.31 to +0.50 | Mild Over-saturation | Minor water haziness or cloudy water during temperature spikes | Light scaling inside salt cells and pool heater tubes | Add diluted Muriatic Acid to trim pH and Total Alkalinity |
| > +0.50 | Severe Scale-Forming | Rough sandpaper-like calcium crusts across pool walls and waterline tile | Severely clogged heat exchangers; premature heater failure | Dose Muriatic Acid; lower TA; partially drain to lower Calcium Hardness |
Step-by-Step Mathematical Walkthrough: Balancing a 20,000-Gallon Plaster Pool
To understand how thermodynamic saturation modeling prevents catastrophic plaster etching and heat exchanger fouling, follow this real-world diagnostic calculation for an in-ground swimming pool in mid-summer.
Field Diagnostic Baseline Test Results
Step 1: Cyanurate Alkalinity Correction
Total Alkalinity measures all titratable bases including bicarbonate (), carbonate (), and cyanurate (). At pH 7.85, the cyanurate correction factor () is 0.33:
Corrected Carbonate Alk = 130 - (60 × 0.33) = 130 - 19.8 = 110.2 ppm
Step 2: Thermodynamic Constant Resolution
- Factor A (TDS 1,100 ppm):
- Factor B (Temp 28.9°C):
- Factor C (CH 420 ppm):
- Factor D (Carb Alk 110.2 ppm):
Step 3: Calculating Saturation pH () and Final LSI
pHs = (9.3 + 0.204 + 2.010) - (2.223 + 2.042)
pHs = 11.514 - 4.265 = 7.249
LSI = Measured pH - pHs = 7.85 - 7.25 = +0.60
Scientific Evaluation: An LSI of +0.60 indicates severe supersaturation ( scaling state). The warm water and elevated hardness will precipitate calcium carbonate crusts across heat exchanger tubes and salt chlorine generator cell plates.
Corrective Action & Prescription
To bring LSI into equilibrium (target LSI: 0.00), lower pH from 7.85 to 7.45 and Total Alkalinity from 130 to 90 ppm. Dosing 64 fl oz (1.89 L) of 31.45% Muriatic Acid restores saturation equilibrium: new , resulting in a balanced final LSI of -0.01.
Protocol: Step-by-Step Dosing Execution
- Measure Baseline Water Chemistry: Utilize a calibrated photometer or FAS-DPD test kit to measure pH, Total Alkalinity, Calcium Hardness, Cyanuric Acid, and Temperature.
- Compute Cyanurate-Corrected Alkalinity: Subtract approximately one-third of the Cyanuric Acid concentration from Total Alkalinity to isolate true carbonate alkalinity.
- Evaluate Thermodynamic LSI State: Assess whether water is aggressive (LSI < -0.30) or scale-forming (LSI > +0.30).
- Dose Reagents Sequentially: Adjust Total Alkalinity first with Sodium Bicarbonate, then Calcium Hardness with Calcium Chloride, and finally pH with diluted Muriatic Acid.
DANGER: Always add acid to water (AAA). Wear chemical splash goggles and heavy-duty nitrile gloves. Never mix muriatic acid with chlorine sanitizers, as toxic chlorine gas (Cl2) will instantly evolve.
Sabana Sarmin
Sabana Sarmin is the founder and curator of AquaMatrix Lab. She oversees the development and standardization of client-side dosing engines, translating published thermodynamic dissociation constants, NIST SRD standard reference data, and EPA/USDA public consensus guidelines into accessible, high-precision web tools.
Consensus Academic References
- ▪ Langelier, W. F. (1936). The Analytical Control of Anti-Corrosion Water Treatment. Journal AWWA, 28(10), 1500-1521.
- ▪ ANSI/APSP/ICC-11 Standard for Water Quality in Public Pools and Spas (2019).
- ▪ NIST Standard Reference Database 46: Critically Selected Stability Constants of Metal Complexes.
Frequently Asked Technical Questions
Why does Cyanuric Acid affect my pool LSI calculation?
Cyanuric acid contributes cyanurate ions (C3H2N3O3-) to Total Alkalinity titration. However, only carbonate species (HCO3- and CO3 2-) buffer calcium carbonate precipitation. AquaMatrix Lab dynamically deducts cyanurate alkalinity according to aqueous dissociation constants.
What is the difference between LSI and Ryznar Stability Index (RSI)?
While LSI measures the thermodynamic driving force for CaCO3 precipitation (pH - pHs), RSI (2*pHs - pH) offers an empirical assessment of scale thickness and long-term corrosion rates.
How much muriatic acid is needed to lower pool pH by 0.2?
In a 15,000-gallon pool with a Total Alkalinity of 100 ppm, approximately 26 fluid ounces (770 mL) of 31.45% muriatic acid will drop pH by approximately 0.2 units.
Related Chemical Engines & Calculators
All Pool & Spa Water Chemistry Engines →遊離残留塩素 & シアヌル酸平衡計算機 (FC/CYA 比率)
シアヌル酸緩衝下の有効殺菌性次亜塩素酸 (HOCl) 濃度とイソシアヌル酸貯蔵量を算出し、塩素ロック現象を未然に防...
次亜塩素酸カルシウム (カルハイポ 68%) プールショック塩素計算機
結合塩素(クロラミン)の酸化分解や藻類除去に必要なショック塩素投入量を高精度に算出します。
硫酸水素ナトリウム (pH降下剤・ドライアシッド) プール添加量計算機
プール水の pH と総アルカリ度を安全に下げる硫酸水素ナトリウム(ドライアシッド)の精密投入量をリットル・m³単位...