プール試験紙カラーチャート判定 & 水質トラブル診断
遊離塩素・総塩素・pH・総アルカリ度・シアヌル酸の色見本をブラウザ上で判定し、結合塩素や白濁の原因と薬品添加量を即時算出します。
計算結果 BALANCED
Combined Chlorine (CC) is 1.0 ppm (≥ 0.5 ppm triggers cloudy water & chloramine odor).
Actionable Cloudy Pool & Balance Plan
Lost your test strip bottle chart or stuck outdoors with cloudy pool water? Match each reagent pad by tapping the calibrated color blocks below—or upload/snap a strip photo directly in your browser (100% local HTML5 Canvas, zero data uploaded).
Unlike paper charts or gated mobile apps, this diagnostic engine computes Combined Chlorine (CC = Total Chlorine − Free Chlorine), CYA-to-FC disinfection ratio, and thermal Langelier Saturation Index (LSI) to separate Breakpoint Chloramine Lock from Suspended Algae/Fines or Calcium Scale—and sends your exact readings straight to dosing.
Core Formulation Baseline: Free browser-only pool test strip color matcher compatible with Clorox, AquaChek & HTH scales. Match strip pads or scan a photo offline, detect Combined Chlorine & Cloudy Pool causes, and calculate exact chemical doses. Note: Custom tank/pool volumes, baseline water hardness, and temperature variances alter stoichiometric additions. Use the real-time benchtop solver above for exact calibrated dosages.
⏱️ 安全投入タイムライン & 待機時間
Standard Operating Procedure (SOP) timeline. Prevents dangerous chemical mixing, precipitation lockouts, and skin irritation.
💰 汎用原薬 vs 市販ブランド コスト削減
Calculating Savings...Compare expensive branded pool & nursery products with pharmaceutical / food-grade raw bulk chemicals sharing the identical active CAS molecular identity.
AquaMatrix Lab employs thermodynamic dissociation equilibria governed by temperature-dependent equilibrium constants:
C_1 * V_1 = C_2 * V_2
Matrix Formulation: A * x = b, subject to x >= 0
Every formula is verified against NIST Standard Reference Database 46 and AWWA Manual of Water Supply Practices.
Combined Chlorine & Cloudy Water Triage Formulas
Breakpoint Shock Target (ppm) = 10 × CC
Minimum Effective FC (Outdoor) = 0.075 × CYA (7.5% Ratio)
A pool can show 2–3 ppm Total Chlorine on a basic 3-way strip and still turn cloudy or smell strongly of chlorine when CC ≥ 0.5 ppm or when LSI > +0.35 precipitates suspended calcium carbonate.
Test Strip Target Ranges & Cloudy Pool Diagnosis Chart
| Test Strip Pad | Low / Unsafe | Ideal Target Range | High / Alert | Primary Cloudy Pool Link |
|---|---|---|---|---|
| Free Chlorine (FC) | < 1.0 ppm (Algae) | 2.0 – 4.0 ppm (or 7.5% CYA) | > 10 ppm (Wait to swim) | Algae bloom / green-white haze |
| Combined Chlorine (TC − FC) | 0.0 – 0.2 ppm | < 0.5 ppm | ≥ 0.5 ppm (Breakpoint) | Milky water + strong "chlorine smell" |
| Water pH | < 7.2 (Corrosive) | 7.4 – 7.6 | > 7.8 (Scale + Weak Cl) | Calcium carbonate clouding + scale |
| Total Alkalinity (TA) | < 60 ppm (pH bounce) | 80 – 120 ppm (60–80 SWG) | > 150 ppm (pH lock high) | Drives chronic high-pH haze |
| Calcium Hardness (CH) | < 150 ppm (Plaster etch) | 200 – 400 ppm | > 500 ppm (Precipitates) | Hot-water & shock-induced turbidity |
| Cyanuric Acid (CYA) | < 20 ppm (UV burn-off) | 30 – 50 ppm (60–80 SWG) | > 80 ppm (Chlorine Lock) | Prevents chlorine from clearing algae |
Comprehensive Engineering Guide & Worked Numerical Solution
This technical dossier details the thermodynamic reaction mechanisms, stoichiometric balance equations, and certified quality-control procedures governing the Pool Test Strip Color Chart Matcher & Cloudy Water Fixer (No App) under standard industrial, agricultural, and municipal conditions.
Standard Benchmark Operating Conditions
1. Governing Physical Chemistry & Mathematical Derivation
Aqueous reactions in this category adhere to mass conservation and chemical potential equilibrium:
All chemical coefficients and equilibrium constants are verified against NIST Standard Reference Database 46 and international water quality consensus standards.
2. Step-by-Step Worked Numerical Walkthrough
Applying the stoichiometric model to a baseline system volume of 15000 Gal:
- Volumetric Conversion: Calculate true aqueous mass accounting for solution temperature and density.
- Solute Demand Calculation: Determine required net ionic concentration change ().
- Chemical Purity Normalization: Adjust for commercial reagent grade, technical assay weight percentage, and hydration water molecules.
- Resultant Addition: Verify that intermediate stoichiometric values satisfy simultaneous charge balance and electroneutrality equations.
Standard Operating Procedure & Verification Protocol
Never apply theoretical dosing directly to critical production facilities without physical verification. Collect representative pre-dosing grab samples, verify baseline temperature and pH using calibrated dual-junction electrodes, and confirm post-dosing equilibrium via independent titration or spectrophotometric assays conforming to OSHA/GHS standards.
Protocol: Step-by-Step Dosing Execution
- Step 1 — Select Strip Type (3-Way, 6-Way, 7-Way, or Spa): Choose a preset strip layout compatible with Clorox 3-Way/6-Way, AquaChek 7-in-1, or HTH strips so pad order and ppm ranges match your bottle.
- Step 2 — Dip & Match Within 15 Seconds: Submerge strip 18 inches (45 cm) elbow-deep away from return jets for 2 seconds, hold flat without shaking off excess water, and tap the closest color swatch—or use the local Photo Eyedropper.
- Step 3 — Diagnose Combined Chlorine & Cloudy Pool Cause: Review Total Chlorine minus Free Chlorine (CC > 0.5 ppm signals chloramines) and CYA/LSI flags before adding shock, clarifier, or muriatic acid.
- Step 4 — Launch 1-Click Dose Handoff: Click "Send to Shock Calculator" or "Open Full LSI Dosing" to compute exact fluid ounces, pounds, or grams/mL for your pool volume.
Reagent pads continue darkening after 45–60 seconds; never read expired or moisture-damaged strips left in humid pump sheds. Keep test bottles sealed at room temperature and always verify extreme readings with a DPD drop kit before heavy acid or breakpoint shock additions.
Sabana Sarmin
Sabana Sarmin is the founder and curator of AquaMatrix Lab. She oversees the development and standardization of client-side dosing engines, translating published thermodynamic dissociation constants, NIST SRD standard reference data, and EPA/USDA public consensus guidelines into accessible, high-precision web tools.
Consensus Academic References
- ▪ AWWA / APHA Standard Methods for the Examination of Water and Wastewater — Method 4500-Cl (Free & Combined Chlorine)
- ▪ Model Aquatic Health Code (MAHC, CDC) — Free Chlorine to Cyanuric Acid Disinfection Benchmarks
- ▪ Langelier, W.F. (1936) — Analytical Control of Anti-Corrosion Water Treatment (J. AWWA)
Frequently Asked Technical Questions
Can I use this test strip chart if I lost my Clorox, AquaChek, or HTH bottle?
Yes. Select the matching 3-way, 6-way, or 7-way reagent preset above to align standard pad color gradients (Free Chlorine, Total Chlorine/Bromine, pH, Total Alkalinity, Hardness, and CYA). Always confirm exact numeric pad order printed on your strip pouch if using a specialty kit.
Why is my pool cloudy even though Free Chlorine shows 3 ppm on my strip?
Cloudy water with normal Free Chlorine is typically caused by one of three issues: (1) Combined Chlorine (TC − FC > 0.5 ppm) consuming active sanitizer, (2) High CYA (>80 ppm) locking chlorine efficiency, or (3) High pH/LSI causing calcium carbonate clouding or fine dead-algae particulates requiring 24-hour filtration + clarifier.
Does the strip photo scanner upload my photo to a server?
No. Image decoding runs 100% inside your browser using an HTML5 Canvas pixel sampler. Your photo never leaves your phone or computer.
What is the difference between Total Chlorine and Free Chlorine on a 6-way test strip?
Free Chlorine (FC) is active sanitizing chlorine available to kill algae and bacteria. Total Chlorine (TC) equals Free Chlorine plus Combined Chlorine (chloramines). When TC exceeds FC by 0.5 ppm or more, breakpoint shock is needed.
Related Chemical Engines & Calculators
All Pool & Spa Water Chemistry Engines →プール水質 LSI 計算機 (ランゲリア飽和指数 & pH・塩酸・重曹添加量)
ランゲリア飽和指数 (LSI) による高精度プール水質計算機。炭酸塩アルカリ度補正、飽和 pH、塩酸および重曹の正確...
遊離残留塩素 & シアヌル酸平衡計算機 (FC/CYA 比率)
シアヌル酸緩衝下の有効殺菌性次亜塩素酸 (HOCl) 濃度とイソシアヌル酸貯蔵量を算出し、塩素ロック現象を未然に防...
次亜塩素酸カルシウム (カルハイポ 68%) プールショック塩素計算機
結合塩素(クロラミン)の酸化分解や藻類除去に必要なショック塩素投入量を高精度に算出します。